Summary of the additive test results

The following chart is summarizing the data of the additive test at the TÜV Nord in Hanover. The index values for the valve clearance of the respective vehicle in cold condition in the admission area are 0.17 to 0.23. As specified by the manufacturer, the outlet valves should have a valve clearance between 0.25 and 0.31. At each measurement the cylinder head temperature was documented at the time of measurement. The indicated data are measurement values, measured by the TÜV Nord within their measures accompanying the trial. You will find the repective official records of the TÜV Nord here. 

Result measured by TÜV Nord in Hanover:                    
Measurement no 1 2 3 4 5 6 7 8 9 10
Date 12.2010 03.2011 06.2011 08.2011 10.2011 12.2011 02.2012 06.2012 07.2012 01.2013
Mileage 3769 16950 30441 45052 54554 65148 75175 91906 101497 113506
Diagnosis meter gas system                    
Gas fuelled operation 53,17 264,09 462,57 661,53 796,40 946,23 1091,15 1329,29 1520,57 1681:48
Gasoline-fuelled operation 06,33 21,02 40,26 57,49 63,30 69,51 81,20 95,30 107,03 135:03
Cylinder head temperature 66 57 55 61 54 60 60 59 58 58
                     
Valve clearance measurement                    
Admission valves                    
1 left 20 20 20 20 20 20 20 20 20 20
1 right 20 20 20 20 20 20 20 20 20 20
2 left 20 20 20 20 20 20 20 20 20 20
2 right 20 20 20 20 20 20 20 20 20 20
3 left 20 20 20 25 20 20 20 20 20 20
3 right 20 20 20 25 20 25 25 25 25 25
4 left 25 20 20 20 20 20 20 20 25 20
4 right 20 20 20 20 20 20 20 20 20 20
Outlet valves                    
1 left 25 25 25 25 25 25 25 25 25 25
1 right 25 25 30 30 30 30 30 30 25 30
2 left 25 25 25 30 30 30 30 30 30 30
2 right 25 25 30 30 30 30 30 30 30 30
3 left 25 30 35 30 35 35 35 35 35 35
3 right 25 30 30 30 30 30 30 30 30 35
4 left 25 25 30 30 30 30 30 30 30 30
4 right 25 25 35 30 30 30 30 30 30 30